Opcode |
Instruction |
Op/En |
64-Bit Mode |
Compat/Leg Mode |
Description |
A8 ib |
TEST AL, imm8 |
I |
Valid |
Valid |
AND imm8 with AL; set SF, ZF, PF according to result. |
A9 iw |
TEST AX, imm16 |
I |
Valid |
Valid |
AND imm16 with AX; set SF, ZF, PF according to result. |
A9 id |
TEST EAX, imm32 |
I |
Valid |
Valid |
AND imm32 with EAX; set SF, ZF, PF according to result. |
REX.W + A9 id |
TEST RAX, imm32 |
I |
Valid |
N.E. |
AND imm32 sign-extended to 64-bits with RAX; set SF, ZF, PF according to result. |
F6 /0 ib |
TEST r/m8, imm8 |
MI |
Valid |
Valid |
AND imm8 with r/m8; set SF, ZF, PF according to result. |
REX + F6 /0 ib |
TEST r/m8*, imm8 |
MI |
Valid |
N.E. |
AND imm8 with r/m8; set SF, ZF, PF according to result. |
F7 /0 iw |
TEST r/m16, imm16 |
MI |
Valid |
Valid |
AND imm16 with r/m16; set SF, ZF, PF according to result. |
F7 /0 id |
TEST r/m32, imm32 |
MI |
Valid |
Valid |
AND imm32 with r/m32; set SF, ZF, PF according to result. |
REX.W + F7 /0 id |
TEST r/m64, imm32 |
MI |
Valid |
N.E. |
AND imm32 sign-extended to 64-bits with r/m64; set SF, ZF, PF according to result. |
84 /r |
TEST r/m8, r8 |
MR |
Valid |
Valid |
AND r8 with r/m8; set SF, ZF, PF according to result. |
REX + 84 /r |
TEST r/m8*, r8* |
MR |
Valid |
N.E. |
AND r8 with r/m8; set SF, ZF, PF according to result. |
85 /r |
TEST r/m16, r16 |
MR |
Valid |
Valid |
AND r16 with r/m16; set SF, ZF, PF according to result. |
85 /r |
TEST r/m32, r32 |
MR |
Valid |
Valid |
AND r32 with r/m32; set SF, ZF, PF according to result. |
REX.W + 85 /r |
TEST r/m64, r64 |
MR |
Valid |
N.E. |
AND r64 with r/m64; set SF, ZF, PF according to result. |
Notes: * In 64-bit mode, r/m8 can not be encoded to access the following byte registers if a REX prefix is used: AH, BH, CH, DH.
Computes the bit-wise logical AND of first operand (source 1 operand) and the second operand (source 2 operand) and sets the SF, ZF, and PF status flags according to the result. The result is then discarded.
In 64-bit mode, using a REX prefix in the form of REX.R permits access to additional registers (R8-R15). Using a REX prefix in the form of REX.W promotes operation to 64 bits. See the summary chart at the beginning of this section for encoding data and limits.
The OF and CF flags are set to 0. The SF, ZF, and PF flags are set according to the result (see the “Operation” section above). The state of the AF flag is undefined.
Same exceptions as in protected mode.